MultiFields — Measurment / Thermal transport test system

Intro.      Module      Spec      Data      Contact

MultiFields·Thermal transport test system

Integrated Solution for Thermal Conductivity, Seebeck and Resistance Measurement

Control of deviations from absolute values of thermal conductivity and Seebeck measurements to less than 5 per cent;

Built-in automatic iterative algorithm for optimal deltaT selection at different temperatures;

One-stop shop for high-precision measurements with specialised measuring instruments;

Block heat transport and thin film thermoelectric coefficient measurements are supported by switching to different measurement modules;

Available for magnetic fields from 1.5 to 400 K and up to 18 Tesla;

Compatible with third party systems such as Oxford TeslatronPT, PPMS, Cryogenics, etc.

Thermal Transport Systems – Specification

01. System working environment

Sample Pole Working Environment

1.5 ~ 400 K, up to 18 T

Adaptable platforms

Adaptation to third party systems such as Oxford TeslatronPT, PPMS, Cryogenics, etc.

02. Thermal transport test performance

Sample Type

Bulk & Film Version*

Heat conductivity

Accuracy:± 5%, from 1.5 ~ 400 K

Measurement range:10 uW/K ~ 100 mW/K

Seebeck coefficient

Accuracy:±5% or ± 100 nV

Measurement range:0.1 uV/K ~ 1 V/K**

Sample size (recommended)

— 2.5*1.5*6 mm2 for 0.1 ~ 2.5 W/m·K
— 1.5*1.5*6 mm2 for 2 ~ 50 W/m·K
— 1.5*1.5*10 mm2 for >30 W/m·K

03. Measuring instrument

Functionality

— 2 channels of thermocouple readout
— 1 Channel Heater Output
— 2 channels of temperature monitoring
1 Channel NanoVolt Gauge***

Sizes

280 mm * 220 mm * 88 mm (W*H*L)

Connector

USB & GPIB

04. Software

Environmental Controls

Temperature, magnetic field, sample chamber status

Measurement type

Thermal conductivity, Seebeck’s coefficient, Nernst’s coefficient, resistivity, Thermal Hall

Functionality

ΔT Corrective Radiation Losses with Automatic Adjustment for Various Temperatures

* Will be discussed in the next section
** Dependent on sample temperature
*** Optional Module

·System Component

Thermal transport – meters

Automatic measuring software

Sample bar

Toolbox

01. Thermal transport · measurement meters

Built-in 2 thermometer monitoring channels, 2 thermocouple channels, 1 high-precision heating power control channel & multiple nanovolt measurement channels.

MultiFields.TTM. Meter

Nanovoltmeter measurement resolution RMS<2 nV

Temperature monitoring measurement resolution RMS< 10 ppm

Measurement Meters – Specification

01. Thermocouple Measurement Module – for monitoring temperature gradients in thermal transport measurements

Channel

2

Ground

±2 mV

Resolution

30 nV

Velocity

10 SPS*

Thermocouple Type

S/K/E/J/T/AuFe

02. HEATER CONTROL MODULE – precise control of heating power in temperature gradients

Channel

1

Realm

0~10 mA (Current)

0~100 mW (Power)

Heater Resistance

1 kOhm

Accuracy

<0.1 % (Power)

1 uV (Voltage)

Speed

10 SPS

03. Thermopotential Measurement Module – Nanovolt Measurement

Channel

1/2可选

Realm

±2 V

Resolution

Input Range

Gain

±2 uV

1 M

±20 uV

100 k

±200 uV

10 k

±2 mV

1 k

±20 mV

128

±200 mV

8

±2 V

1

Speed

10 SPS

Input Impedance

> 1 GOhm

04. RTD thermometer measurement module

Channel

2

Sensor Types

CernoxTM & PT100 & PT1000 & Diode

Realm

0.3 ~ 420 K (CernoxTM CX-1030)

Auto Range

YES

Reverse Current

YES

Calibration Curves

300 Points and 100 Curves MAX

Filter

Kalman Filter

Resolution

0.001%

05. Communications & Interface

Connector

GPIB & USB

Touchscreen Control

5.0 inch TFT touch-screen with 1280 x 720 pixels

Power 

220 VAC, 1 Amp MAX

* SPS: Sample per second

02. Thermal Transport Measurement·Control Software

Real-time measurements, real-time fitting, support for sequence automation statements to write measurements

03. Thermal Transport Measurement · Toolbox

Heat transport measurements require skillful handling and well-prepared experimental accessories to achieve accurate measurements.

TTM. Accessories Kit

Thermal Transportation · Toolbox – Specification

Class

Specification

Standard Sample

1. Standard Sample Pb 4N

Pb wire metallic ,99.99%,  Φ2.0 mm, L 20 mm Alfa

Quartz Massive, 99.99%; 3 mm x 3 mm x 2mm

Glues

3. N-lipids

4. Adhesives – Thermally Conductive Adhesives

Electrically insulating, good thermal conductivity at 2 K, epoxy resin

5. Adhesives-Thermally Conductive Adhesive

Good electrical conductivity, good thermal conductivity at 2 K, epoxy resin

Thermocouple wire

6. Thermocouple wire

Type E thermocouple, chrome plated wire, Φ25 μm

7. AuFe thermocouple wire (optional)

Perforated iron wire, Φ25 μm

Tool

8. Tweezers

Non-magnetic, 140 mm (length)

Sample Mounting Attachment – Block Version

9. Cold side

Copper, Oxygen free, 8 mm * 9 mm * 0.8 mm

10. Heaters

1 kOhm, 0.6 mm * 0.8 mm * 0.4 mm

11. Metal wire

Phosphor bronze, Φ 50 μm

12. M2 Screws

Copper screws, non-magnetic

13. Sample Fixture

For bulk sample preparation only, aluminum alloy

14. Main part

Oxygen-free copper sample tray with BeCu pins, equipped with CernoxTM 1050 calibrating thermometer

Sample Mounting Accessory – Film Version

15. Cold side

Copper, Oxygen-free, 5 mm * 4 mm * 4 mm

16. Metal wires

Phosphor bronze, Φ 50 μm

17. M1.6 Screws

Copper screws, non-magnetic

18. Sample Fixture

For auxiliary mounting of samples, aluminum alloy

19. Main part

Oxygen-free copper sample tray with BeCu pins, equipped with CernoxTM 1050 calibrating thermometer

04.Thermal transport measurements · sample rods

Sample bars with 2 K in-situ vacuum environment

Thermal Transport Testing · Application Examples

Application Cases (1)—

Thermal conductivity of Pb superconducting transition under magnetic field

Sample Information

Pb rod / 99.99% , Alfa

MultiFields Products

1. TTM Systems, meter
2. TTM Systems, probe

Platform

Oxford TeslatronPT

Application Cases (2)—

Fused quartz thermal conductivity behavior

Sample Information

Fused quartz rod

MultiFields Products

1. TTM Systems, meter
2. TTM Systems, probe

Platform

Quantum Design· PPMS

Application Cases (3)—

Nernst effect of Wely Semi-metal sample

Sample Information

Wely-Semimetal Sample

MultiFields Products

1. TTM Systems, meter
2. TTM Systems, probe

Platform

Oxford TeslatronPT

MultiFields
China
Huairou District, Beijing
Building 2, Nonferrous Metals New Materials Science Park, Huairou Science City, Huairou District, Beijing

Tel:(+86) 186 0055 3105
Wechat:186 0055 3105

Websites:multi-field.com
Email:info@multi-field.com